Select "F2" to accept data loss and to re-enable logical drives
Cause
Data was lost while the array was expanded; therefore, the drives have been temporarily disabled. Capacity
expansion failed as:
Cache module or hard drive failed or was removed; expansion progress data was lost.
Expansion progress data could not be read from cache module.
Expansion was aborted due to unrecoverable drive errors.
Expansion was aborted due to cache module errors.
Action
1. Do one of the following:
Press the F1 key to continue with the logical drives disabled.
Press the F2 key to accept the data loss and re-enable the logical drives. Restore data from backup, if
necessary.
Additional actions for specific errors
Cache Module Removed or Failed; Expansion Progress Data Lost. Verify that the cache module is
seated correctly. Replace if necessary.
Expansion Progress Data Could Not Be Read From Cache Module. Verify that the cache module is
seated correctly. Replace if necessary.
Expansion Aborted due to Unrecoverable Drive Errors. Verify failed disks using HPE SSA and
replace as necessary.
Expansion Aborted due to Cache Module Errors. Verify that the cache module is seated correctly.
Replace if necessary.
Restore data from backup, if necessary.
1770-Slot X Drive Array – Disk Drive Firmware Update Recommended
Symptom
1770-Slot X Drive Array – Disk Drive Firmware Update Recommended. Please upgrade firmware on the
following drive model(s) using ROM Flash Components: Model XYZ (minimum version = ####)
Cause
Drive firmware update needed.
1770-Slot X Drive Array – Disk Drive Firmware Update Recommended 137