Select "F2" to accept data loss and to re-enable logical drives
Cause
Data was lost while the array was expanded; therefore, the drives have been temporarily disabled. Capacity
expansion failed as:
• Cache module or hard drive failed or was removed; expansion progress data was lost.
• Expansion progress data could not be read from cache module.
• Expansion was aborted due to unrecoverable drive errors.
• Expansion was aborted due to cache module errors.
Action
1. Do one of the following:
• Press the F1 key to continue with the logical drives disabled.
• Press the F2 key to accept the data loss and re-enable the logical drives. Restore data from backup, if
necessary.
Additional actions for specific errors
• Cache Module Removed or Failed; Expansion Progress Data Lost. Verify that the cache module is
seated correctly. Replace if necessary.
• Expansion Progress Data Could Not Be Read From Cache Module. Verify that the cache module is
seated correctly. Replace if necessary.
• Expansion Aborted due to Unrecoverable Drive Errors. Verify failed disks using HPE SSA and
replace as necessary.
• Expansion Aborted due to Cache Module Errors. Verify that the cache module is seated correctly.
Replace if necessary.
Restore data from backup, if necessary.
1770-Slot X Drive Array – Disk Drive Firmware Update Recommended
Symptom
1770-Slot X Drive Array – Disk Drive Firmware Update Recommended. Please upgrade firmware on the
following drive model(s) using ROM Flash Components: Model XYZ (minimum version = ####)
Cause
Drive firmware update needed.