The HPE Smart Storage Battery is disconnected.
Action
Follow the action that is displayed onscreen to resume the capacity expansion process.
1766-Slot X Drive Array requires System ROM Upgrade
Symptom
1766-Slot X Drive Array requires System ROM Upgrade.
Cause
The System ROM is not the latest version.
Action
Run the FWUPDATE utility. For more information, see "FWUPDATE utility" in the HPE ProLiant Gen9
Troubleshooting Guide, Volume I on the Hewlett Packard Enterprise website.
1768-Slot X Drive Array – Resuming logical drive expansion process
Symptom
1768-Slot X Drive Array – Resuming logical drive expansion process.
Cause
Power was lost while a logical expansion operation was performed.
A controller reset or power cycle occurred while array expansion was in progress.
Action
No action is required.
1769-Slot X Drive Array – Drive(s) Disabled
Symptom
1769- Slot X Drive Array – Drive(s) Disabled due to Failure During Expansion
(Possibly followed by one of the following additional details):
Cache Module Removed or Failed; Expansion Progress Data Lost.
Expansion Progress Data Could Not Be Read From Cache Module.
Expansion Aborted due to Unrecoverable Drive Errors.
Expansion Aborted due to Cache Module Errors.
Select "F1" to continue with logical drives disabled