1. Reseat the I/O modules.
2. Reseat the I/O module cables.
3. Replace the cables, if damaged.
4. If the issue persists, replace the I/O modules.
Installed drives not detected, only I/O module 2 present
1. Reseat the I/O modules.
2. Reseat the I/O module cables.
3. Replace cables, if damaged.
4. If the issue persists, replace I/O module 1.
1778-Slot X Drive Array resuming Automatic Data Recovery (Rebuild) process
Symptom
1778-Slot X Drive Array resuming Automatic Data Recovery (Rebuild) process.
Cause
A controller reset or power cycle occurred while Automatic Data Recovery was in progress.
Action
No action is required.
1779-Slot X Drive Array – Logical drive(s) previously failed
Symptom
1779-Slot X Drive Array – Logical drive(s) previously failed.
Select "F1" to continue with logical drives disabled
Select "F2" to accept data loss and to re-enable logical drives
(Followed by one of the following:)
Logical drive(s) disabled due to possible data loss.
Logical drive(s) reenabled.
Restore data from backup if replacement drive(s) have been installed.
Cause
Previously failed logical drives are attached to the controller.
The system was not powered up or down correctly.
Action
1778-Slot X Drive Array resuming Automatic Data Recovery (Rebuild)
process 141