For more information, see the HPE iLO 4 User Guide on the Hewlett Packard Enterprise website.
1824-Slot X One or more storage cables has failed
Symptom
1824-Slot X One or more storage cables have failed preventing discovery of attached storage. Action: Turn
OFF power and re-attach the failed cables (run SSA to determine failed cables). Replace the cables if errors
persist.
Cause
A cable is not installed correctly.
A cable has failed.
Action
1. Use HPE SSA to determine which cables need to be reattached.
For more information, see the HPE Smart Storage Administrator User Guide on the Hewlett Packard
Enterprise website.
2. Power down the .
3. Reattach the cables.
4. If the issue persists, replace the cables.
For more information, see the maintenance and service guide on the Hewlett Packard Enterprise
website.
1825-Slot X Encryption Failure
Symptom
1825-Slot X Encryption Failure-Non-volatile storage corrupted: Critical Security Parameters erased per policy.
Encrypted drives offline. Action: Use HP Smart Storage Administrator to reestablish CSPs.
Cause
Non-volatile storage is corrupt.
Action
Use HPE SSA to re-establish Critical Security Parameters. For more information, see the HPE Smart Storage
Administrator User Guide on the Hewlett Packard Enterprise website.
1826-Slot X Encryption Failure
Symptom
1826-Slot X Encryption Failure-Encryption engine hardware failure. Encrypted logical drives offline. Encrypted
logical drives are offline until the problem is corrected. Action: Replace the controller to bring encrypted drives
online.
Cause
The controller has failed.