Controller State: The array controller is operating without a memory board and has a bad
volume position
Symptom
Controller State: The array controller is operating without a memory board and has a bad volume position.
Any configuration command (e.g. logical drive creation, array expansion, etc.) or modification to the controller
will result in the loss of all existing data on the disabled volume(s).
Cause
A cache memory module is not installed.
Action
Install a cache memory module.
For more information, see the user guide on the Hewlett Packard Enterprise website.
Controller State: The array controller is operating without a memory board and has an
invalid physical drive connection
Symptom
Controller State: The array controller is operating without a memory board and has an invalid physical drive
connection. Any configuration command (e.g. logical drive creation, array expansion, etc.) or modification to
the controller will result in the loss of all existing data on the disabled volume(s).
Cause
A cache memory module is not installed.
Action
Install a cache memory module.
For more information, see the user guide on the Hewlett Packard Enterprise website.
Controller State: The array controller is operating without a memory board
Symptom
Controller State: The array controller is operating without a memory board (RAID) and contains one or more
logical drives with a RAID level that is not supported in the current configuration. Any configuration command
(e.g. logical drive creation, array expansion, etc.) or modification to the controller will result in the loss of all
existing data on the disabled volume(s).
Cause
A cache memory module is not installed.
Action
Install a cache memory module.
Controller State: The array controller is operating without a memory board and