possible. This drive can be found in box <box number> which is connected to port
<port number> of the array controller <controller name / slot information>.
Message ID: 24588
Severity: Warning
Log message: Sensor number <sensor number> has reported that the internal
temperature has exceeded the preset limit. This sensor is located in box <box
number> which is connected to port <port number> of array controller <controller
name / slot information>. The array controller may attempt to shut down power to
the attached box and/or spin down the installed disk drive(s).
Message ID: 24589
Severity: Warning
Log message: Sensor number <sensor number> has reported that the internal
temperature is nearing the preset temperature limit. This sensor is located in
box <box number> which is connected to port <port number> of array controller
<controller name / slot information>. The array controller may enact
precautionary measures to prevent data loss should the temperature reach the
operating limit.
Message ID: 24590
Severity: Informational
Log message: Sensor number <sensor number> has reported that a previously existing
temperature condition has been corrected. This sensor is located in box <box
number> which is connected to port <port number> of array controller <controller
name / slot information>. All of the temperature sensors in the attached box are
now reporting acceptable temperature levels.
Message ID: 24591
Severity: Warning
Log message: Redundant power supply number <power supply number> has reported a
fault. This power supply is located in box <box number> which is connected to
port <port number> of array controller <controller name / slot information>.
Message ID: 24592
Severity: Informational
Log message: Redundant power supply number <power supply number> is no longer
sensed as being in a failed state. Some possible reasons that would cause this
state change to occur include:
1. The previously failed power supply has returned to an operational state.
2. The previously failed power supply was removed from the chassis.
The power supply state change occurred in box <box number> which is connected to
port <port number> of array controller <controller name / slot information>.
Message ID: 24593
Severity: Informational
Log message: Array controller <controller name / slot information> has reported
that more physical devices were detected than the controller is currently
capable of supporting. Some physical drives will not be accessible.
Message ID: 24594
Severity: Warning
176 HPE Smart Array errors