PROTOCOL_ADAPTER_FAILED - Protocol layer reports that the protocol hardware
has failed; may be a controller failure.
FAULTY_ID_BAY_EMPTY - Drive responds to SCSI ID, but the corresponding bay is
empty.
FAULTY_ID_BAY_OCCUPIED - Bay is occupied by a drive that does not respond to
the corresponding SCSI ID.
FAULTY_ID_INVALID_BAY - Drive responds to an ID that doesn’t have a valid
corresponding bay.
WRITE_RETRIES_FAILED - Unable to complete a write operation after several
retries.
QUEUE_FULL_ON_ZERO - Drive indicates that its queue is full when we have no
requests outstanding to the drive.
SMART_ERROR_REPORTED - Drive has reported a predictive-failure error when
controller is configured to automatically fail [instead of reporting imminent
failure of] drives that report this error.
PHY_RESET_FAILED - Phy reset request failed.
FR_CHKBLK_FAILED_WRITE - Drive failed write command while checking for media
errors.
FR_ATI_TEST_FAILED_WRITE - Drive failed write command while checking for
errors.
OFFLINE_ERASE - Drive is offline due to a Secure Erase operation.
OFFLINE_TOO_SMALL - Drive is offline because it’s a replacement drive that is
too small.
OFFLINE_DRIVE_TYPE_MIX - Drive is offline because it is not the correct type
for this array [SATA vs SAS].
OFFLINE_ERASE_COMPLETE - Drive is offline because a Secure Erase operation has
completed on it but it hasn’t been replaced yet.
Message ID: 24596
Severity: Error
Log message: The <drive type> physical drive located in bay <bay number> is in a
SMART predictive failure state. This drive can be found in box <box number>
which is connected to port <port number> of the array controller <controller
name / slot information>.
Message ID: 24597
Severity: Warning
Log message: The <drive type> physical hard drive located in bay <bay number> is
not supported <not supported reason>. This drive can be found in box <box
number> which is connected to port <port number> of the array controller
<controller name / slot information>.
<not supported reason> values: