Severity: Warning
Log message: Array controller <controller name / slot information> has reported
that either redundant I/O module number <module number> in box <box number> was
removed or the cable to this module was removed. The cable and I/O module were
connected to port <port number> of the array controller.
Message ID: 24611
Severity: Informational
Log message: Array controller <controller name / slot information> has reported
that either redundant I/O module number <module number> in box <box number> was
added or the cable to this module was connected. The cable and I/O module are
connected to port <port number> of the array controller.
Message ID: 24612
Severity: Informational
Log message: Array controller <controller name / slot information> has reported
that box <box number> connected to port <port number> is now marked as repaired
(re-added after a previous failure).
Message ID: 24613
Severity: Informational
Log message: Array controller <controller name / slot information> has reported
that either redundant I/O module number <module number> in box <box number> was
repaired or its path was repaired. Box <box number> is connected to port <port
number> of the array controller.
Message ID: 24614
Severity: Informational
Log message: Array controller <controller name / slot information> has reported
that the external array controller attached to port <port number> has been
disconnected or powered down.
Message ID: 24615
Severity: Informational
Log message: Array controller <controller name / slot information> has reported
that an external array controller was attached to port <port number> or was
previously attached and was powered on.
Message ID: 24616
Severity: Warning
Log message: Array controller <controller name / slot information> is reporting
that an unsupported configuration has occurred with the redundant cabling that
is attached between port <port number> and box <box number>. <firmware
information>. Please check the cabling and ensure that a supported configuration
is being used.
<firmware information> values: