EasyManua.ls Logo

HPE ProLiant Gen9

HPE ProLiant Gen9
460 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
The external Smart Array controller reporting this event is attached to the host
side Smart Array controller <controller name / slot information>.
Message Id: 24752
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that storage box number <box number> was added
to port <port number>. This connection is through I/O module number <module
number> on the storage box.
The external Smart Array controller reporting this event is attached to the host
side Smart Array controller <controller name / slot information>.
Message Id: 24753
Severity: Error
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that storage box number <box number> was removed
from port <port number>. This connection was through I/O module number <module
number> on the storage box. This event can occur when either a sole I/O module
or data cable is removed.
The external Smart Array controller reporting this event is attached to the host
side Smart Array controller <controller name / slot information>.
Message Id: 24754
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis number> has reported that either redundant I/O module number <module
number> in box <box number> was removed or the cable to this module was removed.
The cable and I/O module were connected to port <port number> of the external
controller.
The external Smart Array controller reporting this event is attached to the host
side Smart Array controller <controller name / slot information>.
Message Id: 24755
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis number> has reported that either redundant I/O module number <module
number> in box <box number> was added or the cable to this module was connected.
The cable and I/O module are connected to port <port number> of the external
controller.
The external Smart Array controller reporting this event is attached to the host
side Smart Array controller <controller name / slot information>.
Message Id: 24756
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis number> has reported that box <box number> connected to port <port
number> is now marked as repaired (re-added after a previous failure).
The external Smart Array controller reporting this event is attached to the host
side Smart Array controller <controller name / slot information>.
Message Id: 24757
HPE Smart Array errors 211

Table of Contents

Other manuals for HPE ProLiant Gen9

Related product manuals