Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis number> has reported that either redundant I/O module number <module
number> in box <box number> was repaired or its path was repaired. Box <box
number> is connected to port <port number> of the external array controller.
The external Smart Array controller reporting this event is attached to the host
side Smart Array controller <controller name / slot information>.
Message Id: 24758
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that redundant path number <path number> for the
<drive type> physical drive located in bay <bay number> has either failed or
been removed.
The external Smart Array controller reporting this event is attached to the host
side Smart Array controller <controller name / slot information>.
Message Id: 24759
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis number> has reported that an unsupported configuration has occurred
with the redundant cabling that is attached between port <port number> and box
<box number>. <firmware information>. Please check the cabling and ensure that a
supported configuration is being used.
The external Smart Array controller reporting this event is attached to the host
side Smart Array controller <controller name / slot information>.
Message Id: 24760
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that an unsupported configuration has occurred
with the redundant cabling that is attached to port <port number>. <firmware
information>. Please check the cabling and ensure that a supported configuration
is being used.
The external Smart Array controller reporting this event is attached to the host
side Smart Array controller <controller name / slot information>.
Message Id: 24761
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that an unsupported configuration has occurred
with the redundant cabling that is attached to port <port number>. Please check
the cabling and ensure that a supported configuration is being used.
The external Smart Array controller reporting this event is attached to the host
side Smart Array controller <controller name / slot information>.
Message Id: 24762
Severity: Informational
Log message:
212 HPE Smart Array errors