External Smart Array controller number <controller number> located in the MSA
chassis labeled as <chassis label> is reporting the following flash operation:
"<firmware message>."
The firmware was flashed from:
Revision: <old revision number>
to
Revision: <new revision number>
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24763
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported an uncorrectable read error during rebuild
operations for logical drive <logical drive number>. The uncorrectable media
defects are between logical block address <lba number 1> and logical block
address <lba number 2>. The host will be unable to read some blocks between this
address range until the blocks are overwritten. The logical drive rebuild is
continuing so that the volume can regain fault tolerance. Capacity expansion
operations must be avoided while the affected blocks are unreadable.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24764
Severity: Warning
Log message :The external Smart Array controller located in the MSA chassis labeled
as <chassis label> is reporting that the <drive type> physical hard drive
located in bay <bay number> is not supported <not supported reason>.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
<not supported reason> values:
because it is a singled ported drive
because it is a SATA drive
because it is smaller than the drive it is replacing
because it is of an unrecognized type
because it contains an unsupported RIS configuration
Message Id: 24765
Severity: Informational
Log message: The MSA chassis labeled as <chassis label> has reported that battery
pack number <battery pack number> located on controller number <controller
number> has been <inserted / removed>.
The external Smart Array controller reporting this operation is attached to the
host side Smart Array controller <controller name / slot information>.
Message Id: 24766
HPE Smart Array errors 213