Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> is reporting that the <drive type> physical hard drive
located in bay <bay number> is in a SMART predictive failure state.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24767
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that more physical devices were detected than
the controller is currently capable of supporting. Some physical drives will not
be accessible.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24768
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that the storage enclosure attached to port
<port number> with chassis serial number <serial number> has had power supply
number <power supply number> <inserted / removed>.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24769
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that fan number <fan number> located on fan
module <fan module number> was <inserted / removed>.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24770
Severity: Error
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that fan number <fan number> located on fan
module <fan module number> has failed. The external Smart Array controller may
attempt to shut down power and/or spin down the installed disk drive(s).
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24771
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that fan number <fan number> located on fan
module <fan module number> is reporting a degraded condition.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24772
214 HPE Smart Array errors