Action
1. If this drive is part of a non-fault-tolerant configuration:
a. Back up all data on the drive.
b. Replace the drive.
c. Restore all data to the new drive.
Solution 2
Action
1. If this drive is part of a fault-tolerant configuration:
a. Bring all of the drives in the array online.
b. Replace the drive.
Physical Drive State: SATA drives are not supported for configuration and should be
disconnected from this controller
Symptom
Physical Drive State: SATA drives are not supported for configuration and should be disconnected from this
controller.
Cause
The drives are not supported by the controller.
Action
Replace the physical drive with a drive supported by the controller. To locate a supported option, review the
product QuickSpecs on the Hewlett Packard Enterprise website.
Physical Drive State: Single-ported drives are not supported for configuration and should
be disconnected from this controller
Symptom
Physical Drive State: Single-ported drives are not supported for configuration and should be disconnected
from this controller.
Cause
The drives are not supported by the controller.
26 Physical Drive State: SATA drives are not supported for configuration
and should be disconnected from this controller