EasyManua.ls Logo

HPE ProLiant Gen9

HPE ProLiant Gen9
460 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
sysName
cpqHoTrapFlags
cpqDaPhyDrvCntlrIndex
cpqDaPhyDrvBusNumber
cpqDaPhyDrvBay
cpqDaPhyDrvModel
cpqDaPhyDrvFWRev
cpqDaPhyDrvSerialNum
Supporting SNMP Trap Description: “Factory threshold passed for a physical drive.”
NT Event ID: 1062 (Hex)0xc4350426 (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: Drive Array Logical Drive Status Change.
Log Message: Logical drive number %5 on the array controller in slot %4 has a new status of %2.
SNMP Trap: cpqDa3LogDrvStatusChange - 3008 in CPQIDA.MIB
Symptom: Logical Drive Status Change. This trap indicates that the agent has detected a change in the status
of a drive array logical drive. The variable cpqDaLogDrvStatus indicates the current logical drive status.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaLogDrvStatus
Supporting SNMP Trap Description: “Status is now [cpqDaLogDrvStatus].”
NT Event ID: 1063 (Hex)0xc4350427 (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: Drive Array Spare Drive Status Change.
Log Message: The spare drive in slot %4, port %5, bay %6 has a new status of %2.
SNMP Trap: cpqDa4SpareStatusChange - 3017 in CPQIDA.MIB
Symptom: Spare Drive Status Change. This trap indicates that the agent has detected a change in the status
of a drive array spare drive. The variable cpqDaSpareStatus indicates the current spare drive status.
User Action: If the spare drive status is failed, replace the drive.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaSpareStatus
cpqDaSpareCntlrIndex