cpqDaSpareBusNumber
cpqDaSpareBay
Supporting SNMP Trap Description: “Spare Status is now [cpqDaSpareStatus].”
NT Event ID: 1064 (Hex)0xc4350428 (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: Drive Array Physical Drive Status Change.
Log Message: The physical drive in slot %4, port %5, bay %6 with serial number “%7”, has a new status of
%2.
SNMP Trap: cpqDa5PhyDrvStatusChange - 3029 in CPQIDA.MIB
Symptom: Physical Drive Status Change. This trap indicates that the agent has detected a change in the
status of a drive array physical drive. The variable cpaDaPhyDrvStatus indicates the current physical drive
status.
User Action: If the physical drive status is failed(3) or predictiveFailure(4), replace the drive.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaPhyDrvStatus
cpqDaPhyDrvCntlrIndex
cpqDaPhyDrvBusNumber
cpqDaPhyDrvBay
cpqDaPhyDrvModel
cpqDaPhyDrvFWRev
cpqDaPhyDrvSerialNum
cpqDaPhyDrvFailureCode
Supporting SNMP Trap Description: “Physical Drive Status is now [cpqDaPhyDrvStatus].”
NT Event ID: 1065 (Hex)0xc4350429 (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: Drive Array Accelerator Status Change.
Log Message: The array accelerator board attached to the array controller in slot %4 has a new status of %2.
SNMP Trap: cpqDa5AccelStatusChange - 3025 in CPQIDA.MIB
Symptom: Accelerator Board Status Change. This trap indicates that the agent has detected a change in the
status of an array accelerator cache board. The current status is represented by the variable
cpqDaAccelStatus.
User Action: If the accelerator board status is permDisabled(5), you may need to replace the accelerator
board.
Supporting SNMP Trap Data:
HPE Insight Management Agents for Servers for Windows 343