sysName
cpqHoTrapFlags
cpqDaCntlrSlot
cpqDaCntlrModel
cpqDaAccelSerialNumber
cpqDaAccelTotalMemory
cpqDaAccelStatus
cpqDaAccelErrCode
Supporting SNMP Trap Description: “Status is now [cpqDaAccelStatus].”
NT Event ID: 1066 (Hex)0xc435042a (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: Drive Array Accelerator Bad Data.
Log Message: The array accelerator board attached to the array controller in slot %4 is reporting that it
contains bad cached data.
SNMP Trap: cpqDa5AccelBadDataTrap - 3026 in CPQIDA.MIB
Symptom: Accelerator Board Bad Data. This trap indicates that the agent has detected an array accelerator
cache board that has lost battery power. If data was being stored in the accelerator cache memory when the
server lost power, that data has been lost.
User Action: Verify that no data has been lost.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaCntlrSlot
cpqDaCntlrModel
cpqDaAccelSerialNumber
cpqDaAccelTotalMemory
Supporting SNMP Trap Description: “Accelerator lost battery power. Data Loss possible.”
NT Event ID: 1067 (Hex)0xc435042b (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: Drive Array Accelerator Battery Failed.
Log Message: The array accelerator board attached to the array controller in slot %4 is reporting a battery
failure.
SNMP Trap: cpqDa5AccelBatteryFailed - 3027 in CPQIDA.MIB
Symptom: Accelerator Board Battery Failed. This trap indicates that the agent has detected a battery failure
associated with the array accelerator cache board.
User Action: Replace the Accelerator Cache Board.
Supporting SNMP Trap Data: