sysName
cpqHoTrapFlags
cpqDaCntlrSlot
cpqDaCntlrModel
cpqDaAccelSerialNumber
cpqDaAccelTotalMemory
Supporting SNMP Trap Description: “Battery status is failed.”
NT Event ID: 1068 (Hex)0xc435042c (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: SCSI Controller Status Change.
Log Message: The SCSI controller in slot %4, SCSI bus %5 has a new status of %2.
SNMP Trap: cpqScsi3CntlrStatusChange - 5005 in CPQSCSI.MIB
Symptom: SCSI Controller Status Change. The Insight Agent has detected a change in the controller status of
a SCSI Controller. The variable cpqScsiCntlrStatus indicates the current controller status.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqScsiCntlrStatus
Supporting SNMP Trap Description: “Status is now [cpqScsiCntlrStatus].”
NT Event ID: 1069 (Hex)0xc435042d (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: SCSI Logical Drive Status Change.
Log Message: The SCSI logical drive with SCSI target %6 connected to SCSI bus %5 of the controller in slot
%4, SCSI has a new status of %2.
SNMP Trap: cpqScsi3LogDrvStatusChange - 5021 in CPQSCSI.MIB
Symptom: Logical Drive Statues Change. The Storage Agent has detected a change in the status of a SCSI
logical drive. The current logical drive status is indicated in the cpqScsiLogDrvStatus variable.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqScsiLogDrvStatus
cpqScsiLogDrvCntlrIndex
cpqScsiLogDrvBusIndex
cpqScsiLogDrvIndex
cpqScsiLogDrvOsName