Supporting SNMP Trap Description: “Status is now [cpqScsiLogDrvStatus].”
NT Event ID: 1070 (Hex)0xc435042e (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: SCSI Physical Drive Status Change.
Log Message: The SCSI physical drive with SCSI target %6 connected to SCSI bus %5 of the controller in
slot %4 has a new status of %2.
SNMP Trap: cpqScsi5PhyDrvStatusChange - 5020 in CPQSCSI.MIB
Symptom: Physical Drive Status Change. The Storage Agent has detected a change in the status of a SCSI
physical drive. The current physical drive status is indicated in the cpqScsiPhyDrvStatus variable.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqScsiPhyDrvStatus
cpqScsiPhyDrvCntlrIndex
cpqScsiPhyDrvBusIndex
cpqScsiPhyDrvIndex
cpqScsiPhyDrvVendor
cpqScsiPhyDrvModel
cpqScsiPhyDrvFWRev
cpqScsiPhyDrvSerialNum
cpqScsiPhyDrvOsName
Supporting SNMP Trap Description: “Status is now [cpqScsiPhyDrvStatus].”
NT Event ID: 1075 (Hex)0x84350433 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Fan Status Change.
Log Message: The %6 %7 storage system connected to SCSI bus %5 of the controller in slot %4 has a new
status of %2.
SNMP Trap: cpqSs3FanStatusChange - 8008 in CPQSTSYS.MIB
Symptom: Storage System fan status change. The agent has detected a change in the Fan Status of a
storage system. The variable cpqSsBoxFanStatus indicates the current fan status.
User Action: If the fan status is degraded or failed, replace any failed fans.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSsBoxFanStatus
Supporting SNMP Trap Description: “Storage System fan status changed to [cpqSsBoxFanStatus].”
NT Event ID: 1076 (Hex)0xc4350434 (cpqstmsg.dll)
346 HPE Insight Management Agents for Servers for Windows