Supporting SNMP Trap Description: “Side panel is re-installed on unit.”
NT Event ID: 1104 (Hex)0x84350450 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Fault Tolerant Power Supply Degraded.
Log Message: The fault tolerant power supply in the %6 %7 storage system connected to SCSI bus %5 of the
controller in slot %4 has a degraded status. Restore power or replace any failed power supply.
SNMP Trap: cpqSs4PwrSupplyDegraded - 8015 in CPQSTSYS.MIB
Symptom: A storage system power supply status has been set to degraded.
User Action: Restore power or replace any failed storage system power supply.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSsBoxFltTolPwrSupplyStatus
Supporting SNMP Trap Description: “A storage system power supply unit has become degraded.”
NT Event ID: 1107 (Hex)0xc4350453 (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: SCSI Tape Drive Status Change.
Log Message: The tape drive with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4 has
a new status of %2.
SNMP Trap: cpqTape4PhyDrvStatusChange - 5016 in CPQSCSI.MIB
Symptom: Tape Drive Status Change. The Storage Agent has detected a change in the status of a Tape drive.
The current physical drive status is indicated in the cpqTapePhyDrvStatus variable.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqTapePhyDrvCntlrIndex
cpqTapePhyDrvBusIndex
cpqTapePhyDrvScsiIdIndex
cpqTapePhyDrvStatus
Supporting SNMP Trap Description: “Status is now [cpqTapePhyDrvStatus].”
NT Event ID: 1119 (Hex)0x8435045f (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: SCSI Tape Drive Head Needs Cleaning.