Log Message: The tape drive with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4
needs to have a cleaning tape inserted and run.
SNMP Trap: cpqTape3PhyDrvCleaningRequired - 5008 in CPQSCSI.MIB
Symptom: Tape Drive Cleaning Required trap. The Insight Agent has detected a tape drive that needs to have
a cleaning tape inserted and run. This causes the tape drive heads to be cleaned.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqTapePhyDrvCondition
Supporting SNMP Trap Description: “Status is now [cpqTapePhyDrvCondition].”
NT Event ID: 1120 (Hex)0x84350460 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: SCSI Tape Drive Cleaning Tape Needs Replacing.
Log Message: The tape drive with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4
needs the cleaning tape replaced.
SNMP Trap: cpqTape3PhyDrvCleanTapeReplace - 5009 in CPQSCSI.MIB
Symptom: Tape Drive Cleaning Tape Needs Replacing. The Insight Agent has detected that an autoloader
tape unit has a cleaning tape that has been fully used and therefore needs to be replaced with a new cleaning
tape.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqTapePhyDrvCondition
Supporting SNMP Trap Description: “Status is now [cpqTapePhyDrvCondition].”
NT Event ID: 1121 (Hex)0x84350461 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: IDE Drive Status Degraded.
Log Message: The IDE drive %4 has a degraded status and should be scheduled for replacement.
SNMP Trap: cpqIdeDriveDegraded - 14001 in CPQIDE.MIB
Symptom: An IDE drive status has been set to degraded.
User Action: The drive should be scheduled for replacement. For detailed information on a component
replacement, see the appropriate Maintenance and Service Guide.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqIdeIdentIndex
Supporting SNMP Trap Description: “IDE drive [cpqIdeIdentIndex] has become degraded.”