209-DIMM Configuration Error
Symptom
209-DIMM Configuration Error - Installed DIMM configuration does NOT support configured AMP Mode.
System will operate in Advanced ECC Mode. Action: Ensure DIMM configuration meets requirements for
configured AMP mode.
Cause
The DIMM configuration does not match the configured AMP mode.
Action
Install DIMMs in a supported configuration.
For more information, see the user guide on the Hewlett Packard Enterprise website.
210-Processor X: Quick Path Interconnect (QPI) Link Degradation
Symptom
210-Processor X: Quick Path Interconnect (QPI) Link Degradation. A QPI link on this processor is operating in
a degraded performance state.
Cause
The processor is not seated correctly.
The processor socket is contaminated.
The processor has failed.
CAUTION:
Before removing or replacing any processors, be sure to follow the processor troubleshooting guidelines
in "Performing Processor Procedures in the Troubleshooting Process" in the HPE ProLiant Gen9
Troubleshooting Guide, Volume I: Troubleshooting. Failure to follow the recommended guidelines can
cause damage to the system board, requiring replacement of the system board.
Action
1. Make sure the processor is correctly installed and seated.
For more information, see "Processor issues" in the HPE ProLiant Gen9 Troubleshooting Guide, Volume I
on the Hewlett Packard Enterprise website.
2. If the issue persists, make sure that the processor socket is not contaminated.
3. If the issue persists, replace the processor.
For more information, see the maintenance and service guide on the Hewlett Packard Enterprise
website.
212-CPU failed
Symptom
212-CPU failed.