222-DIMM Configuration Error – The DIMM configuration is incorrect
Symptom
222-DIMM Configuration Error – The DIMM configuration is incorrect and prevents the system from initializing
memory. System video output may have additional information regarding failure. The system is halted.
Cause
Memory is not installed correctly.
Action
Install DIMMs in a supported configuration.
For more information, see the user guide on the Hewlett Packard Enterprise website.
223-Memory Error – A memory error occurred
Symptom
223-Memory Error. A memory error occurred which prevents the system from initializing memory. System
video output may have additional information regarding failure. The system is halted.
Cause
A memory error occurred.
Action
Check the video output or the Integrated Management Log for additional information.
For more information, see "Integrated Management Log" in the HPE ProLiant Gen9 Troubleshooting Guide,
Volume I on the Hewlett Packard Enterprise website.
224-Power fault detected – FlexLOM X
Symptom
224-Power fault detected – FlexLOM X. Action: Unplug the server (or remove the server if a blade or SL-
server) and re-seat the indicated FlexLOM.
Cause
The FlexibleLOM is not fully seated on the connector.
Action
1. Power down the server.
2. Do one of the following: