• sysName
• cpqHoTrapFlags
Supporting SNMP Trap Description: “Remote Insight mouse cable disconnected.”
NT Event ID: 1117 (Hex)0x8435045d (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: The Remote Insight Board has detected that the external power cable is disconnected.
SNMP Trap: cpqSm2ExternalPowerCableDisconnected - 9010 in CPQSM2.MIB
Symptom: External Power Cable Disconnected. The Remote Insight external power cable has been
disconnected.
Supporting SNMP Trap Data:
• sysName
• cpqHoTrapFlags
Supporting SNMP Trap Description: “Remote Insight external power cable disconnected.”
NT Event ID: 1118 (Hex)0x4435045e (cpqsvmsg.dll)
Log Severity: Information (1)
Log Message: The Fault Tolerant Power Supply Sub-system has been returned to the OK state.
SNMP Trap: cpqHe4FltTolPowerSupplyOk - 6048 in CPQHLTH.MIB
Symptom: The fault tolerant power supply condition has been set back to the OK state for the specified
chassis and bay location.
Supporting SNMP Trap Data:
• sysName
• cpqHoTrapFlags
• cpqHeFltTolPowerSupplyChassis
• cpqHeFltTolPowerSupplyBay
• cpqHeFltTolPowerSupplyStatus
• cpqHeFltTolPowerSupplyModel
• cpqHeFltTolPowerSupplySerialNumber
• cpqHeFltTolPowerSupplyAutoRev
• cpqHeFltTolPowerSupplyFirmwareRev
• cpqHeFltTolPowerSupplySparePartNum
• cpqSiServerSystemId
Supporting SNMP Trap Description: “The Power Supply is OK on Chassis [cpqHeFltTolPowerSupplyChassis],
Bay [cpqHeFltTolPowerSupplyBay], Status [cpqHeFltTolPowerSupplyStatus], Model
[cpqHeFltTolPowerSupplyModel], Serial Num [cpqHeFltTolPowerSupplySerialNumber], Firmware
[cpqHeFltTolPowerSupplyFirmwareRev].”
NT Event ID: 1123 (Hex)0x84350463 (cpqsvmsg.dll)
412 HPE Insight Management Agents for Servers for Windows