Supporting SNMP Trap Data:
• sysName
• cpqHoTrapFlags
• cpqSeCpuUnitIndex
• cpqSeCpuSlot
• cpqSeCpuName
• cpqSeCpuSpeed
• cpqSeCpuStep
• cpqSeCpuPowerpodStatus
• cpqSeCpuExtSpeed
• cpqSeCpuSocketNumber
• cpqSeCpuHwLocation
Supporting SNMP Trap Description: “Processor in Slot [cpqSeCpuSlot] Power supply status is
[cpqSeCpuPowerpodStatus].”
NT Event ID: 1115 (Hex)0x8435045b (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: A computer cover has been removed since last system start up. Be sure the system cover is
installed properly. This situation may result in improper cooling of the system due to air flow changes caused
by the missing cover.
SNMP Trap: cpqSiHoodRemoved - 2001 in CPQSINFO.MIB
Symptom: The access panel is removed. The access panel status has been set to removed. The access
panel is not installed properly. This situation may result in improper cooling of the system due to air flow
changes caused by the missing access panel.
User Action: Replace the access panel and be sure that it is installed properly. Verify that the system is
working properly.
Supporting SNMP Trap Data:
• sysName
• cpqHoTrapFlags
Supporting SNMP Trap Description: “Hood is removed from unit.”
NT Event ID: 1116 (Hex)0x8435045c (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: The Remote Insight Board has detected that the mouse cable is disconnected.
SNMP Trap: cpqSm2MouseCableDisconnected - 9009 in CPQSM2.MIB
Symptom: Mouse Cable Disconnected. The Remote Insight mouse cable has been disconnected.
Supporting SNMP Trap Data:
HPE Insight Management Agents for Servers for Windows 411