Replace the DIMM. For more information, see the maintenance and service guide on the Hewlett Packard
Enterprise website.
284-DIMM Failure – Processor X, DIMM Y
Symptom
284-DIMM Failure – Uncorrectable Memory Error – Processor X, DIMM Y. Action: Replace Failed DIMM.
Cause
A DIMM has failed.
Action
Replace the DIMM. For more information, see the maintenance and service guide on the Hewlett Packard
Enterprise website.
285-DIMM Failure
Symptom
285-DIMM Failure – Uncorrectable Memory Error – Memory Board X, DIMM Y or Processor X, DIMM Z (exact
DIMM could not be determined). Action: Attempt to isolate which DIMM is failed and replace it.
Cause
A DIMM has failed.
Action
Attempt to isolate the DIMM experiencing the error and replace it. For more information, see "General
memory issues" in the HPE ProLiant Gen9 Troubleshooting Guide, Volume I on the Hewlett Packard
Enterprise website.
285-DIMM Failure
Symptom
285-DIMM Failure – Uncorrectable Memory Error – Processor X, DIMM Y or Processor X, DIMM Z (exact
DIMM could not be determined). Action: Attempt to isolate which DIMM is failed and replace it.
Cause
A DIMM has failed.