Action
Replace the spare drive with a drive that is at least the size of the smallest data drive in the array.
For more information, see the product maintenance and service guide on the Hewlett Packard Enterprise
website.
Cache module: The cache for this controller is temporarily disabled since a snapshot is in
progress
Symptom
Cache module: The cache for this controller is temporarily disabled since a snapshot is in progress. The
controller requires a reboot to enable the cache. Until the reboot occurs, cache module operations such as
Expansion, Extension, and Migration are disabled.
Cause
A snapshot is in progress.
Action
Reset the controller to enable the cache.
Cache module operations such as Expansion, Extension, and Migration are disabled until the reboot
completes.
Cache module: The batteries were hot-removed
Symptom
Cache module: The batteries were hot-removed.
Cause
The cache module batteries were removed.
Action
Install the batteries.
For more information, see the maintenance and service guide on the Hewlett Packard Enterprise website.
Cache module: The cache is disabled because a capacitor has failed to charge to an
acceptable level
Symptom
Cache module: The cache is disabled because a capacitor has failed to charge to an acceptable level.
Cause
The cache module battery will not charge.
Action
Replace the cache module battery.
8 Cache module: The cache for this controller is temporarily disabled since
a snapshot is in progress