Action
If the error persists, replace the NVDIMM.
For more information, see the maintenance and service guide on the Hewlett Packard Enterprise website.
345-NVDIMM Error – Erase Error
Symptom
345-NVDIMM Error – Erase Error - Processor X, DIMM Y. NVDIMM could not be erased and future backups
are not possible. Action: Save NVDIMM contents to other media to preserve data and then replace the
NVDIMM.
Cause
The last erase operation failed and the NVDIMM contains the only copy of the restored data. If the is reset or
powered down, the backup will not complete and data will be lost.
Action
1. Save the contents of the NVDIMM to other media to preserve the data.
CAUTION:
Contents of the NVDIMM must be saved to another media source immediately. If the is reset or
powered down prior to preserving the data, the data will be lost.
2. Replace the NVDIMM.
3. Sanitize the new NVDIMM.
4. Copy the preserved data to the new NVDIMM.
For more information, see the HPE 8GB NVDIMM User Guide on the Hewlett Packard Enterprise
website.
346-NVDIMM Error – Arming Error
Symptom
346-NVDIMM Error – Arming Error - Processor X, DIMM Y. NVDIMM could not be armed and future backups
are not possible. Action: Save NVDIMM contents to other media to preserve data and then replace the
NVDIMM.
Cause
The restore operation succeeded but the NVDIMM cannot be armed for backup due to an NVDIMM controller
failure. As a result, the NVDIMM is reported to the operating system as read-only.
Action
1. Save the contents of the NVDIMM to other media to preserve the data.
2. Replace the NVDIMM.
3. Sanitize the new NVDIMM.
4. Copy the preserved data to the new NVDIMM.
86 345-NVDIMM Error – Erase Error