Solution 1
Cause
The contains an unsupported mixture of DIMM types.
Action
Remove all LRDIMMs from the .
For more information, see the maintenance and service guide on the Hewlett Packard Enterprise website.
For more information about the types of memory supported in the , see the product QuickSpecs on the
Hewlett Packard Enterprise website.
Solution 2
Action
Remove all NVDIMMs from the .
For more information, see the maintenance and service guide on the Hewlett Packard Enterprise website.
For more information about the types of memory supported in the , see the product QuickSpecs on the
Hewlett Packard Enterprise website.
350-NVDIMM Population Error
Symptom
350-NVDIMM Population Error ā Processor X, DIMM Y. NVDIMMs and RDIMMs are in the incorrect order on
Channel Z. NVDIMMs on the channel should be closest to the CPU. Action: Install DIMMs in correct order.
ā System Halted!
Cause
NVDIMMs and RDIMMs are not installed in the correct order.
Action
Follow the population guidelines for installing DIMMs and NVDIMMs in a .
For more information, see the HPE 8GB NVDIMM User Guide on the Hewlett Packard Enterprise website.
351-IMPORTANT: HPE Smart Storage Battery is not charged sufficiently
Symptom
351-IMPORTANT: HPE Smart Storage Battery is not charged sufficiently to support the NVDIMMs installed in
the system.
Cause
The system is configured to wait for the battery to charge but the system does not have enough battery to
handle all NVDIMMs.
88 350-NVDIMM Population Error