Action
1. Wait for the battery to charge sufficiently so that the will continue to boot.
2. Alternately, press the ESC key to skip waiting for the battery to charge.
352-IMPORTANT: HPE Smart Storage Battery is not charged sufficiently
Symptom
352-IMPORTANT: HPE Smart Storage Battery is not charged sufficiently to support the NVDIMMs installed in
the system. Action: System configured to not wait for battery to charge. NVDIMMs not armed to support
backup.
Cause
• The system is not configured to wait for the HPE Smart Storage Battery to charge.
• The ESC key was pressed to skip waiting for the battery to charge.
Action
Wait for the battery to charge sufficiently so that the will continue to boot.
353-IMPORTANT: Possible Password Corruption
Symptom
353-IMPORTANT: Possible Password Corruption. The PW authentication algorithm detected an issue which
has been corrected. Action: If a PW was not previously configured, remove the PW using the Password
Disable Switch.
Cause
A password was lost or corrupted.
Action
Set the Password Disable Switch (S5) to the ON position to remove the password.
To locate the system maintenance switch bank, see the user guide on the Hewlett Packard Enterprise
website.
354-LRDIMM Memory Configuration Issue
Symptom
354-LRDIMM Memory Configuration Issue – The current BIOS requires all memory channels to be populated
with the same number of LRDIMMs. Action: Populate all channels with the same number of LRDIMMs.
Cause
An incorrect number of LRDIMMs is installed on a memory channel.
Action
Install the same number of LRDIMMs on all memory channels.