358-IMPORTANT: Processor X, DIMM Y
Symptom
358-IMPORTANT: Processor X, DIMM Y – The installed NVDIMM has a Supercap attached. This is not
supported. Action: Remove the Supercap from Processor X, DIMM Y.
Cause
An unsupported capacitor pack is attached to an installed NVDIMM. In HPE Proliant servers, power is
provided to the NVDIMMs by the HPE Smart Storage battery.
Action
Remove the unsupported capacitor pack from the NVDIMM in Processor X, slot Y.
359-NVDIMM Population Error
Symptom
359-NVDIMM Population Error – Processor 1 must have at least one RDIMM installed when NVDIMMs are
present in the system. Action: Install an RDIMM on Processor 1.
Cause
At least one standard DIMM is not installed on Processor 1, as required in the population guidelines.
Action
Install a regular DIMM on Processor 1.
For more information, see the user guide on the Hewlett Packard Enterprise website.
When HPE 8 GB NVDIMMs are installed in a , all regular DIMMs in the must be RDIMMs. For more
information, see the HPE 8GB NVDIMM User Guide on the Hewlett Packard Enterprise website.
360-IMPORTANT: The System Programmable Logic Device revision in this system does not
meet minimum requirements for operation with NVDIMMs
Symptom
360-IMPORTANT: The System Programmable Logic Device revision in this system does not meet minimum
requirements for operation with NVDIMMs. All NVDIMM functionality has been disabled. Action: Remove all
NVDIMMs from the system.
Cause
NVDIMMs are not supported in this .
Action
Remove all NVDIMMs from the .
For more information, see the maintenance and service guide on the Hewlett Packard Enterprise website.