For more information, see the HPE 8GB NVDIMM User Guide on the Hewlett Packard Enterprise website.
373-NVDIMM Error
Symptom
373-NVDIMM Error – NVDIMM(s) have been removed from Processor X. All NVDIMMs on Processor X have
been disabled. Action: Re-install missing NVDIMM or sanitize all NVDIMMs on Processor X.
Solution 1
Cause
One or more NVDIMMs were removed from this and the has NVDIMM-N Memory Interleaving enabled.
Action
Reinstall the missing NVDIMMs.
For more information, see the user guide on the Hewlett Packard Enterprise website.
Solution 2
Action
Sanitize all NVDIMMs on Processor X to begin using the smaller interleaved set.
For more information, see the HPE 8GB NVDIMM User Guide on the Hewlett Packard Enterprise website.
374-NVDIMM Error
Symptom
374-NVDIMM Error – Processor X, DIMM Y received a memory initialization or uncorrectable error. All
NVDIMMs on Processor X are disabled. Action: Sanitize all NVDIMMs on Processor X. If problem persists,
replace the NVDIMM.
Cause
The has NVDIMM-N Memory Interleaving enabled and one of the following occurred:
Action
1. Reseat the NVDIMMs and all DIMMs in the .
2. Sanitize all NVDIMMs on Processor X.
3. If the error persists, replace the NVDIMM.
For more information, see the HPE 8GB NVDIMM User Guide on the Hewlett Packard Enterprise
website. For removal and replacement procedures, see the maintenance and service guide on the
Hewlett Packard Enterprise website.