EasyManua.ls Logo

Hypertherm Powermax65 SYNC - Plasma power supply interior, front

Hypertherm Powermax65 SYNC
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service Parts
2
24 810440 Service Parts and Procedures Powermax65/85 SYNC
Plasma power supply interior, front
For replacement procedures, refer to the following:
Replace the control PCB and the ribbon cable on page 96
Replace the work lead receptacle on page 69
Replace the torch quick-disconnect receptacle on page 71
Item
Part
number
Description and kit contents
1 528026 Kit: Control PCB and adjustment knob
141472 Control PCB
108797 Adjustment knob
075418 Screw: #4 X 1/4, pan head (3)
2 428068 Kit: Ribbon cable for control PCB, 14 cm (5.5 inches)
223024 Ribbon cable that connects the control PCB to the DSP PCB
3 428070 Kit: Powermax65/85 SYNC work lead receptacle
228364 Work lead receptacle
4 528024 Kit: Powermax65/85 SYNC torch quick-disconnect receptacle
229884 Torch quick-disconnect receptacle housing
015920 Torch quick-disconnect receptacle
075899 Retention nut
075693 Screw: #6 X 1/2, pan head (4)
108076 Grommet
3
1
1
4
2
3
5
2
4

Table of Contents

Other manuals for Hypertherm Powermax65 SYNC

Related product manuals