Service Procedures for the Gas Line
4
Powermax65/85 SYNC Service Parts and Procedures 810440 83
Install the air filter bowl and filter element
1. Vertically align the filter bowl and push it up into the
receptacle in the rear panel.
2. Turn the filter bowl 45 degrees to the left until you hear
a click.
Replace the air filter assembly
For kit contents, refer to Plasma power supply interior, fan side on page 21.
This kit contains an extra gas tube. This procedure uses the shortest gas tube in the kit.
Remove the air filter assembly
1. Set the plasma power supply switch to OFF (O), disconnect the power cord from the power
source, and disconnect the gas supply.
2. Remove the plasma power supply cover and the component barrier. Refer to page 49.
3. Loosen the rear panel. Refer to page 57.
4. Remove the air filter bowl and air filter element. Refer to
page 81.
5. Push-to-disconnect both ends of the gas tube .
6. From the outside of the rear panel, remove the gas
fitting from the air filter assembly.
7. Remove the 3 screws from the rear panel.
8. Remove the air filter assembly from the plasma power
supply.
1
2
1
2
3
3

Table of Contents

Other manuals for Hypertherm Powermax65 SYNC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax65 SYNC and is the answer not in the manual?

Hypertherm Powermax65 SYNC Specifications

General IconGeneral
BrandHypertherm
ModelPowermax65 SYNC
CategoryWelding System
LanguageEnglish

Related product manuals