Service Procedures for the Cover, Panels, and Connectors
3
Powermax65/85 SYNC Service Parts and Procedures 810440 51
Install the component barrier and plasma power supply cover
1. Push in the sides of the
component barrier so that the
component barrier bends out
slightly down the center.
2. Put the sides of the component
barrier inside the plasma power
supply frame .
WARNING
SHOCK HAZARD
You can get a serious electric shock if you touch exposed plasma power
supply components. Electric shock can seriously injure or kill you.
You must install the component barrier and the plasma power supply cover.
Never operate the plasma power supply unless the component barrier and the
plasma power supply cover are in position.
1
2
1
2