Service Procedures for the Cover, Panels, and Connectors
3
52 810440 Service Parts and Procedures Powermax65/85 SYNC
3. Fold the top of the component barrier onto
the top edge of the power PCB, inside the
plasma power supply frame and under the
end panel bracket.
4. Make sure that all of the wires that are
connected to the power PCB are behind the
component barrier.
5. Put the cover on the plasma power supply.
Do not pinch any wires.
6. Install the 16 screws on the plasma power
supply cover. Tighten the screws to 1.7 N·m
(15 lbf·in).