Service Procedures for the Cover, Panels, and Connectors
72 810440 Service Parts and Procedures Powermax65/85 SYNC
8. Push-to-disconnect the 90° gas inlet fitting from the torch
quick-disconnect receptacle.
9. Remove the following components from the torch
quick-disconnect receptacle:
Retention nut
Ring terminal
Washer
10. Push the torch quick-disconnect receptacle out
through the torch quick-disconnect receptacle housing.
11 . Remove the 4 screws from the torch quick-disconnect
receptacle housing.
12. Remove the torch quick-disconnect receptacle housing from
the front panel.