EN
8 - TROUBLES – CAUSES - SOLUTIONS SMART320
8 - Pag. 2 / 4
8.1 GENERAL FAILURES
TROUBLES CAUSES SOLUTIONS
[MOD20] Check the electrical connection.
Open guard. Close the guard.
Emergency devices on. Disable the emergency devices.
The bar feeder cannot start
Motor thermal circuit breaker
burnt.
Reset the motor thermal circuit
breaker with the special buttons.
The bar feeder has been reset
but the automatic cycle cannot
start.
No lathe signal.
Check the electrical connection with
the lathe.
The pneumatic devices do not
respond to controls.
[MOD25] Check the air system.
The first feeding and feeding
are stopped unexpectedly.
Motor thermal circuit breaker
burnt.
Reset the motor thermal circuit
breaker with the special buttons.
8.2 BAR MAGAZINE – Failures
TROUBLES CAUSES SOLUTIONS
During the loading phase the
bar cannot enter into the
magazine
The bar alignement plates are
too low
Adjust the position of the plates
The first bar in the magazine
fails to drop into the guide
channel
The bar alignement plates are
not correctly adjusted.
Adjust the position of the plates