5 - ADJUSTMENT AND SETUP SMART320
EN
5 - Pag. 13 / 20
5.3.2 Bar guide plates - Adjustment
Preliminary procedure
Remove the upper guard.
Close the upper guide channel by pressing
on the keyboard (before the guard
opening) or the key on the solenoid valve for
guide channel opening/closing.
Bar guide plate adjustment
Loosen the handle (A), lift the plate and tighten
the handle (A); repeat this operation on all the
plates.
Prepare two bar remnants at least 1,200 mm
long.
Load the two bars into the magazine, loosen
the handle (A) and let the plates drop against
the bars.