5 - ADJUSTMENT AND SETUP SMART320
EN
5 - Pag. 7 / 20
5.3.1 Guide channels, half-bushings, bar pusher and collet - Replacement
• When the magazine is empty (no bars) set the
bar feeder to manual mode
.
• Press
on the keyboard or use the crank
so as to bring the bar pusher to its back limit
stop.
• Remove the upper guard.
• Open the upper guide channels using the
manual control on the solenoid valve.
• Remove and replace the bar pusher.