HD2 Series Inverter Basic Operation Guidelines
-96-
Command switches to keypad
When this terminal is valid, the running command
channel will switch to keypad compulsorily. If this
function becomes invalid, the running command channel
will revert to the original state.
Command switches to
terminal
When this terminal is valid, the running command
channel will switch to terminal compulsorily. If this
function becomes invalid, the running command channel
will revert to the original state.
Command switches to
communication
When this terminal is valid, the running command
channel will switch to communication compulsorily. If this
function becomes invalid, the running command channel
will revert to the original state.
When this terminal is valid, motor pre-exciting will be
started until this terminal becomes invalid.
Zero out power consumption
quantity
After this command becomes valid, the power
consumption quantity of the inverter will be zeroed out.
Maintain power consumption
quantity
When this command is valid, current operation of the
inverter will not impact the power consumption quantity.
Source of upper torque limit
switches to keypad
When this command is valid, the upper limit of the torque
will be set by keypad.
Position reference point input
Valid only for S1, S2, and S3.
Disable spindle orientation
Spindle orientation is invalid.
Spindle zeroing/local position
zeroing
Spindle positioning is triggered.
Spindle zero position selection
1
Spindle zero position selection 1.
Spindle zero position selection
2
Spindle zero position selection 2.
Spindle scale division
selection 1
Spindle scale division selection 1.
Spindle scale division
selection 2
Spindle scale division selection 2.
Spindle scale division
selection 3
Spindle scale division selection 3.
Position/speed control
switchover terminal
Terminal for switching between position control and
speed control.
Pulse input is invalid when the terminal is valid.
Used to clear the input deviation of position loop.