HD2 Series Inverter Function Parameter List
-175-
Function
code
Name
Description
Default
value
Modify
current)
5: Output current (0–Twice the motor rated
current)
6: Output voltage (0–1.5 times the inverter rated
voltage)
7: Output power (0–Twice the motor rated power)
8: Set torque (0–Twice the motor rated torque)
9: Output torque (Absolute value, 0–+/- Twice the
motor rated torque)
10: AI1 input (0–10V/0–20mA)
11: AI2 input (0–10V)
12: AI3 input (0–10V/0–20mA)
13: HDIA input (0.00–50.00kHz)
14: Value 1 set through Modbus/Modbus TCP
communication (0–1000)
15: Value 2 set through Modbus/Modbus TCP
communication (0–1000)
16: Value 1 set through
PROFIBUS/CANopen/DeviceNet communication
(0–1000)
17: Value 2 set through
PROFIBUS/CANopen/DeviceNet communication
(0–1000)
18: Value 1 set through Ethernet communication
(0–1000)
19: Value 2 set through Ethernet communication
(0–1000)
20: HDIB input (0.00–50.00kHz)
21: Value 1 set through
EtherCAT/PROFINET/EtherNet IP communication
(0–1000)
22: Torque current (bipolar, 0–Triple the motor
rated current)
23: Exciting current (bipolar, 0–Triple the motor
rated current)
24: Set frequency (bipolar, 0–Max. output
frequency)
25: Ramp reference frequency (bipolar, 0–Max.
output frequency)