Intel
®
Server Board S5500BC TPS Appendix B: Sensor Tables
Revision 1.8 Intel order number: E42249-009 133
Full Sensor Name
(Sensor name in SDR)
Sensor #
Platform
Applicability
Sensor Type
Event /
Reading Type
Event Offset
Triggers
Contrib. To
System Status
Assert
/ De-
assert
Readabl
e
Value /
Offsets
Event
Data
Rearm
Stand-
by
Processor 1 Thermal
Control %
(P1 Therm Ctrl %)
64h
All
Temperature
01h
Threshold
01h
[u] [c,nc]
nc = Degraded
c = Non-fatal
As
and
De
Analog
Trig Offset
A
Processor 2 Thermal
Control %
(P2 Therm Ctrl %)
65h
Dual
processor
only
Temperature
01h
Threshold
01h
[u] [c,nc]
nc = Degraded
c = Non-fatal
As
and
De
Analog
Trig Offset
A
Processor 1 VRD Temp
(P1 VRD Hot)
66h
All
Temperature
01h
Digital
Discrete
05h
01 - Limit
exceeded
Fatal
As
and
De
Trig Offset
M
Processor 2 VRD Temp
(P2 VRD Hot)
67h
Dual
processor
only
Temperature
01h
Digital
Discrete
05h
01 - Limit
exceeded
Fatal
As
and
De
Trig Offset
M
Catastrophic Error
(CATERR)
68h
All
Processor
07h
Digital
Discrete
03h
01 State
Asserted
Non-fatal
As
and
De
Trig Offset
M
CPU Missing
(CPU Missing)
69h
All
Processor
07h
Digital
Discrete
03h
01 State
Asserted
Fatal
As
and
De
Trig Offset
M
IOH Thermal Trip
(IOH Thermal Trip)
6Ah
All
Temperature
01h
Digital
Discrete
03h
01 State
Asserted
Fatal
As
and
De
Trig Offset
M
X