Intel
®
Server Board S5500BC TPS Platform Management
Revision 1.8 Intel order number: E42249-009 49
The mounted device is visible to (and useable by) the operating
system and BIOS in both pre-boot and post-boot states.
The mounted device shows up in the BIOS boot order and it is possible to change the
BIOS boot order to boot from this remote device.
It is possible to install an operating system on an empty drive using the remotely
mounted device. This may also require the use of KVM-r to configure the operating
system during install.
4.2.4 Availability
The default inactivity timeout is 30 minutes, which you can change through the embedded web
server.
Media redirection sessions will persist across system reset but not across an AC power loss.
4.2.5 Web Services for Management (WS-MAN)
The BMC firmware supports the Web Services for Management (WS-MAN) specification.
4.2.6 Lightweight Directory Authentication Protocol (LDAP)
The BMC firmware supports the Lightweight Directory Authentication Protocol (LDAP) for user
authentication. Note that IPMI users/passwords and sessions are not supported over LDAP.
4.2.7 Embedded Web server
The BMC provides an embedded web server for out of band management. User authentication
is handled by IPMI user names and passwords. Base functionality for the embedded web server
includes:
Power Control Limited control based on IPMI user privilege.
Sensor Reading Limited access based on IPMI user privilege.
SEL Reading Limited access based on IPMI user privilege.
KVM/Media Redirection Limited access based on IPMI user privilege. Only available
when the RMM3 is present.
IPMI User Management Limited access based on IPMI user privilege.
The web server is available on all enabled LAN channels. See Appendix B for Integrated BMC
core sensors.