Server Board S5500BC TPS BIOS Setup Utility
Revision 1.8 Intel order number: E42249-009 77
Setup Item
Options
Help Text
Comments
Clear System Event
Log
Enabled
Disabled
If enabled, clears the System Event Log. All current
entries will be lost.
Note: This option is reset to [Disabled] after a reboot.
FRB-2 Enable
Enabled
Disabled
Fault Resilient Boot (FRB).
If enabled, the BIOS programs the BMC watchdog
timer for approximately 6 minutes. If the BIOS does
not complete POST before the timer expires, the BMC
resets the system.
O/S Boot Watchdog
Timer
Enabled
Disabled
If enabled, the BIOS programs the watchdog timer
with the timeout value selected. If the OS does not
complete booting before the timer expires, the BMC
resets the system and an error is logged.
Requires OS support or Intel Management Software.
O/S Boot Watchdog
Timer Policy
Power Off
Reset
If the OS boot watchdog timer is enabled, this is the
system action taken if the watchdog timer expires.
[Reset] - System performs a reset.
[Power Off] - System powers off.
Grayed out when O/S Boot
Watchdog Timer is
disabled.
O/S Boot Watchdog
Timer Timeout
5 minutes
10 minutes
15 minutes
20 minutes
If the OS watchdog timer is enabled, this is the
timeout value used by the BIOS to configure the
watchdog timer.
Grayed out when O/S Boot
Watchdog Timer is
disabled.
Plug & Play BMC
Detection
Enabled
Disabled
If enabled, the BMC is detectable by OSs that support
plug and play loading of an IPMI driver. Do not enable
if your OS does not support this driver.
ACPI 1.0 Support
Enabled
Disabled
[Enabled] - Publish ACPI 1.0 version of FADT in Root
System Description Table.
May be required for compatibility with OS versions
that only support ACPI 1.0.
Needs to be [Enabled] for
Windows 2000 support.
Console Redirection
View/Configure console redirection information and
settings.
Takes the user to the
Console Redirection
screen.
System Information
View system information
Takes the user to the
System Information
screen.
5.3.2.4.1 Console Redirection Screen
The Console Redirection screen allows the user to enable or disable console redirection and to
configure the connection options for this feature.
To access this screen from the Main screen, select Server Management > Console
Redirection.

Table of Contents

Other manuals for Intel SC5650BCDP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel SC5650BCDP and is the answer not in the manual?

Intel SC5650BCDP Specifications

General IconGeneral
BrandIntel
ModelSC5650BCDP
CategoryServer
LanguageEnglish

Related product manuals