Chapter 7 — Commands
112 ESim for the PC4 and PF8 Printer Programmer’s Reference Manual
An example of a PF8 printer configuration label.
UC - Command Reply Accept Character Control
Purpose: This command specifies a prompt acknowledge character which
the printer returns on the RS-232 or USB channel to the host
after each command execution with no error reply before
proceeding with the next command.
Syntax: UCp
1
.
Remarks: Default is no Command Reply Accept Character (command
UC0).
UC Command Parameter Descriptions
Parameter Description
p
1
Specifies the desired reply character by its ASCII
decimal value (0-255).
If p
1
is anything other than numerical characters
or the value is 0, there is no Command Reply
Accept character (default).

Table of Contents