EasyManua.ls Logo

Intermec EasyCoder PC4 - US - Enable Error Reporting

Intermec EasyCoder PC4
170 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 7 — Commands
118 ESim for the PC4 and PF8 Printer Programmer’s Reference Manual
US - Enable Error Reporting
Purpose: This command is used to enable the status reporting feature with
optional direct recovery.
Syntax: US [A] [B] [E]
.
Remarks: Any or all parameters can be activated at the same time. Refer to
Appendix A for information on error types.
Parameters are saved in Flash memory.
The format of the error messages is controlled by the eR
command.
Example:
The table shows an example of the US command with a reply.
US Command Parameter Descriptions
Parameter Description
A If any error of type A occurs, the printer attempts
to directly recover and continue in normal mode
with no stop for recovery. Often performed with
the Feed key.
B If any error of type A occurs, the printer attempts
to directly recover and continue in normal mode
with no stop for recovery. Often performed with
the Feed key.
E Error 13 LTS reply control (label taken sensor).
Returns error 13 if LTS detects a label before and
after printing.
Command Reply Explanation
USABE
<ACK> Activate all error flags.
eRQ,6,R
Setup user-defined error/status character control to Q for
<XOFF> and R for <XON>.
N
Clears image buffer errors.
AA
Erroneous command type A (syntax error).
P
<NAK>01Q Print image buffer with error 01,
R Direct recovery error 01 (type A) and continue.