Chapter 7 — Commands
ESim for the PC4 and PF8 Printer Programmer’s Reference Manual 59
p
5
Alphanumerical support (optional):
N= Numerical support. Anything other than digit
and leading spaces in DATA causes error 03.
A = Alpha support: Base 10 on digits, base 26 on
letters (default).
Anything else than digit, leading spaces, and
uppercase alpha characters in DATA causes error
03.
Wrap around:
0
9 goes back to 0.
A
Z goes back to A.
B = Alphanumerical support: Base 36
Anything other than digit, leading spaces, and
uppercase alpha characters in DATA causes error
03.
Wrap around:
0
9 A Z 0.
9 goes to A. Z goes back to 0.
[-] A single leading minus sign in the prompt field
causes the prompt to be sent one time only after
the form is retrieved (Keyboard display unit only,
see below).
[--] A double leading minus sign in the prompt field
causes the prompt to be suppressed (Keyboard
display unit only, see below).
“PROMPT” An ASCII text field to transmit to the Keyboard
display unit or host via the serial interface each
time a form containing this command is retrieved.
It usually requests the operator to enter the
starting value for the counter.
C- Counter Parameter Descriptions (continued)
Parameter Description