Radar Field Analyser - RFA641 Edition Date: 28-Feb-18
For each index the following information is presented:
– Reply video in Volts or dBm
– Interrogation number
– Max and min reply voltage level and power level.
– Detailed interrogation information.
– Detailed reply information, decoded from the reply video.
The full 256 μs window is stored for each interrogation, so it can contain the full Mode S reply
waveform. Video can be viewed in voltage or dBm power according to the receiver used for the
logging (RFA receiver). Select the interrogation of interest by moving the index slider. The info will
be updated accordingly.