NOTE: To avoid scratching the chassis, ensure that the ejector is fully open.
Figure 59: Remove a JNP10K-PWR-AC2 Power Supply from an MX10004
6. Rotate the capve screw away from the faceplate of the power supply to release the latch.
7. Wear heat-protecve gloves before you remove the power supply from the chassis.
8. Taking care not to touch the power supply output connecons, pins, leads, or solder connecons,
place one gloved hand under the power supply to support it. Grasp the power supply handle with
your other hand and pull the power supply completely out of the chassis.
CAUTION: Do not bump the output connecons. If the connecon hits a solid
object, it could damage the power supply.
9. Place the JNP10K-PWR-AC2 power supply on an anstac surface for it to cool down before
placing the power supply in an anstac bag for storage.
10. Install the replacement JNP10K-PWR-AC2 power supply.
153