A cover panel for the empty slot if you are not replacing the RCB
CAUTION: In base conguraons, removal of the RCB causes the system to shut down.
In redundant conguraons, removal of the funconing RCB causes the system to
reboot and start the elecon process for a new primary.
To remove an MX10004 RCB:
1. Place an anstac bag or anstac mat on a at, stable surface.
2. Use the following CLI commands to take the RCB oine:
user@host>request vmhost power-off other-routing engine
Power-off the vmhost ? (yes,no?
yes
Initiating vmhost shutdown...
warning: Initiating Junos shutdown...
shutdown: [pid 42862]
Shutdown NOW!
user@host>request chassis cb slot
slot-number
offline
You can use the show chassis environment cb | match State CLI command to verify that the RCB is oine.
user@host>show chassis environment cb | match State
State Online Master
State Offline
3. Wrap and fasten one end of an ESD strap around your bare wrist, and connect the other end of the
strap to the ESD point on the chassis (see Figure 84 on page 188).
4. Simultaneously rotate the RCB handles counterclockwise to unseat the RCB.
190